THE PERFECT INSULATION SYSTEM FOR ALL BUILDINGS

Insulation Plaster

Heat Insulation

Water Insulation

Fire Protection

Sound Insulation

Breathable

Antibakteriyel


Natura, Healty, Environmentalist

Light

Stabil Insulation Value

Economic


Easy and Rapid Application


Texture Compatibility and Long Life

Insulation Plaster – Exterior

A ready-mixed facade insulation plaster containing Portland cement, expanded silicates and inorganic fillers. It is modified with additives, which are not harmful to health and environment, according to European filler directives and ISO requirements. It fulfils WATERPROOF, HEAT, SOUND and FIRE insulation conditions.

Technical Specifications Explanation
Packing 50 L/Bag(±%2)
Appearance White Powder
Application Temperature -5°C +40°C
Application Thickness 10 mm – 50 mm
Application Time 45 minutes
Method of Application Steel Trowel – Pump
First Drying 1 hour
Setting Time 72 hours
Fire Response Class A1
Theoretical Powder Consumption 14-16 L/m²/cm
Dry Density 240 Kg/m³
Thermal Conductivity 0,047 W/mK
Compressive Strength CSII (2,2 N/mm²)
Water vapor permeability 8
Capillary Water Absorption W1
Adhesion Strength 3,2 Kgf/cm
Sound Insulation (2cm Thickness) 22 db/500 Hz.
Fire Prevention (2cm) F120 / 120 minutes

 

USAGE AREAS

It is used directly on the exterior walls of the buildings, columns and beams, on rough and fine plaster, brick, pumice bloc. Primer, must be used necessarily on concrete, gas concrete and painted surfaces.

SURFACE PREPARATION

Blistered paint and spaced plasters are scraped off the surface. 4-5 notches per 10 cm² press on painted surfaces. The application surface should be cleaned from dust. Priming must be done on painted surfaces.

APPLICATION

Laths that determine the thickness are adhered to the prepared surfaces. Between two laths, is filled with a steel trowel or plasterer trowel and gauged. Following the first dry (~ 1-2 hours later ), the slats are removed from the surface and the spaces are filled and the pattern is drawn. if is dry when touched, (12-24 hours later) decorative plaster is drawn. No foreign matter should be added to the prepared mixture. (Lime, Plaster, Cement, etc.)

APPLICATION DETAILS

In manual application, it should be mixed with ~ 8-10 liters of water with low speed (400-600 rev/min) drill for 3-4 minutes. In machine application, it should be pumped to the surface by mixing with 8-10 liters of water in average. When the desired thickness is reached, it should be allowed to dry.

APPLICATION CONDITIONS

Application surface and ambient temperature should be above -5°C. Considering excessive moisture loss at temperatures above +40 °C, mixing water should be increased and the surface should be kept moist by wetting for 1 day after the surface hardening phase.

ISSUES TO BE CONSIDERED

Avoid application under strong wind or sun. The time increases at low temperatures and the time decreases at high temperatures. It should not be applied on frozen, melting or freezing surfaces within 24 hours. Appropriate plaster mesh should be used at different material junctions and points where movement may be considered.

STORAGE TRANSPORT

Protect from frost, rain and other weather conditions. 70 Bags in 1 pallet is 3.500 L.

ENVIRONMENTAL IMPACTS

Not classified as dangerous.